Horizontally NSM CFRP strip reinforcing concrete structures are a new type of reinforcing method, as they require a small groove depth compared with that of the traditional NSM strengthening method. In order to explore the effect and mechanism of the embedding depth of horizontally NSM CFRP strip on interfacial bond performance, the single shear pull-out test was used to compare and analyze the bond properties of concrete specimens reinforced with horizontally NSM CFRP strips, EB CFRP strips, and NSM CFRP strips, and explore the effect of horizontally NSM reinforcement methods. Then, the influ...