In most industrial applications, it is difficult to obtain complete demagnetization fault signals of all conditions with labels for permanent magnet synchronous motor (PMSM), and motors are not allowed to be disassembled, so non-contact diagnostic methods are essential. A non-contact fault diagnosis method using magnetic leakage signal based on wavelet scattering convolution network (WSCN) and semi-supervised deep rule-based (SSDRB) classifier is proposed. Through magnetic equivalent circuit model analysis, the magnetic leakage signal on motor surface is selected as fault signal. To avoid comp...