版权说明 操作指南
首页 > 成果 > 详情

A new optimization design for grounding grid

认领
导出
下载 Link by DOI
反馈
分享
QQ微信 微博
成果类型:
期刊论文
作者:
Hu, Haize*;Luo, Richeng;Fang, Mengge*;Zeng, Shuiling;Hu, Feiyu
通讯作者:
Hu, Haize;Fang, Mengge
作者机构:
[Hu, Haize; Zeng, Shuiling] Jishou Univ, Coll Informat Sci & Engn, Jishou, Peoples R China.
[Fang, Mengge; Hu, Feiyu; Luo, Richeng] Changsha Univ Sci & Technol, Sch Elect & Informat Engn, Changsha, Hunan, Peoples R China.
通讯机构:
[Hu, Haize] J
[Fang, Mengge] C
Jishou Univ, Coll Informat Sci & Engn, Jishou, Peoples R China.
Changsha Univ Sci & Technol, Sch Elect & Informat Engn, Changsha, Hunan, Peoples R China.
语种:
英文
关键词:
Lightning;Lightning protection;Modal analysis;ATP-EMTP;Counterattack;Dual port;Grounding grids;Grounding resistance;Electric grounding
期刊:
International Journal of Electrical Power & Energy Systems
ISSN:
0142-0615
年:
2019
卷:
108
页码:
61-71
基金类别:
This work is supported by National Natural Science Foundation of China (NO. 61363033 ).
机构署名:
本校为通讯机构
院系归属:
电气与信息工程学院
摘要:
In this paper, a new approach for designing groudging grid is proposed. The design is based on constracting an auxiliary annular grounding grid and transforming the lingtning rod's grounding poing from main grounding grid to auxiliary grounding grid. Modal analysis and softwave simulataes is employed to obtain the transformed lightning current (and the voltage) and the reduced ressitance. The dual port model is used to calculate the impedance value of the grounding grid. The calculation results of the model are compared with the standard ground...